Skip to content
Harbin Institute of Technology Robotics·· 2026-08-14FeaturedAI score65

HIT's Wu Zhiguang team develops adaptive magnetically controlled nanorobot swarm platform, achieving navigation in the spinal canal of mice and non-human primates

AI summary

Professor Wu Zhiguang's team at Harbin Institute of Technology (HIT), together with collaborators, developed an adaptive magnetically controlled nanorobot platform that can form swarm motion patterns such as vortex, chain, and ribbon under external magnetic field drive, and achieved targeted navigation within the spinal canal in mice and non-human primates. The results were published in Science Advances.

Source: Harbin Institute of Technology Robotics · robot.hit.edu.cn

Why it matters

The research team released experimental results on navigation of magnetically controlled nanorobot swarms in non-human primates. Readers interested in the medical translation of micro- and nanorobots can learn about its technical approach.

Full text · AI translation

Recently, the joint research team of Professor Wu Zhiguang from our university's Faculty of Life Science and Medicine and the National Key Laboratory of Robot Technology and Systems developed an adaptive magnetically controlled nanorobot platform that can form various collective motion modes such as vortex-like, chain-like, and ribbon-like patterns under the drive of an external magnetic field, and achieve directional navigation within the spinal canal in mice and non-human primates, providing a new technical approach for precise drug delivery for central nervous system diseases and the medical translation of micro-nano robots. The research results were published under the title "Adaptive intrathecal nanorobotics in mice and nonhuman primates for navigated CNS therapy" in Science Advances.

In vivo collective navigation of micro/nano-robots in nonhuman primates for the treatment of central nervous system diseases

Treating central nervous system diseases has long faced the challenges of "unable to deliver, unable to retain, unable to control." Due to the blood-brain barrier, the blood-spinal cord barrier, and the complex anatomical structure of the spinal canal, conventional drug delivery methods often struggle to precisely deliver therapeutic agents to lesion areas. To address the challenge of precise delivery in treating central nervous system diseases, the research team proposed a biomimetic reconfigurable nanorobot composite system. Composed of magnetic nanoparticles, model drugs, neutrophil membrane-derived vesicles, and stem cell-derived exosomes, among other components, the system combines magnetic responsiveness, a biomimetic interface, and drug delivery functions. By regulating the frequency and polarization of an external rotating magnetic field, the nanorobots can self-organize into group structures of different morphologies in a cerebrospinal fluid environment, thereby adapting to the narrow, non-uniform, and nerve-bundle-filled complex space within the spinal canal.

Control system for micro/nano-robots in nonhuman primates in vivo (top), swarm control (middle) and intrathecal control (bottom)

Research shows that among various swarm patterns, vortex-like nanorobot swarms exhibit superior overall performance in intrathecal navigation. This pattern can form high-density aggregates in cerebrospinal fluid while maintaining good motion stability and directional controllability, helping to overcome problems such as slow passive drug diffusion and insufficient spatial targeting. Compared with chain-like and ribbon-like swarm structures, vortex swarms are better suited for long-distance migration within centimeter-scale spinal cavities and sub-millimeter nerve bundle gaps.

To validate the platform's in vivo navigation capability, the research team conducted experiments in a spinal cord injury mouse model. The results showed that, under robotic-arm-assisted magnetic field driving, the nanorobots could migrate directionally along the spinal canal toward the injury site and significantly increased the enrichment of therapeutic components at lesions in the central nervous system. Compared with static intrathecal injection or intravenous injection, magnetic vortex navigation markedly improved targeting efficiency and prolonged the residence time of therapeutic components in the body. Furthermore, the research team built an intrathecal navigation platform in non-human primates that combined medical imaging, robotic-arm-assisted magnetic fields, and other systems. The experiments showed that the nanorobots could migrate directionally from the lumbar injection site under magnetic field driving. This result indicates that the platform is not only applicable to small animal models but also has the potential to bridge the anatomical differences in scale from rodent models to humans, providing an important basis for future clinical translation.

Harbin Institute of Technology was the first affiliation of the paper. Professor Wu Zhiguang and Professor Zhang Lihai of the Chinese People's Liberation Army General Hospital were co-corresponding authors of the paper. Lu Yumeng, a master's student in the Department of Life Sciences and Medicine, Professor Fan Xinjian of Soochow University, and Fan Chengjuan, chief physician at the Second Affiliated Hospital of Harbin Medical University, were co-first authors. Scholars from institutions including the UK Comprehensive Cancer Centre and Imperial College London, and the Harbin Institute of Technology Chongqing Research Institute, participated in this research.

This project was supported by the National Key Research and Development Program, the National Natural Science Foundation of China, and autonomous research projects of the State Key Laboratory of Robotics and Systems, among others.

Paper link: https://www.science.org/doi/10.1126/sciadv.aec2918

News link:https://news.hit.edu.cn/2026/0811/c1510a243187/page.htm