Xiao Ningmeng, author at 3D Vision Workshop, published a practical workflow for HandBot-S2 camera intrinsics calibration and camera-LiDAR extrinsics calibration. Intrinsics calibration uses Kalibr together with an AprilGrid calibration board; the article provides acquisition requirements and the kalibr_calibrate_cameras run command; HandBot-S2 offers optional calibration code. The calibration acquisition requirements are: calibration board images must be clear with no motion blur, the device should be placed stationary, and data should be collected for about 10–20 seconds; if the reprojection error is greater than 1 pixel, recollect, avoiding blur, occlusion, and low-texture regions.
Report timeline
- Full Workflow for Camera Intrinsic and Camera-LiDAR Extrinsic Calibration on HandBot-S2
This article details the practical workflow for completing camera intrinsic calibration and camera-LiDAR extrinsic calibration on the HandBot-S2. Intrinsic calibration uses Kalibr with an AprilGrid calibration board, and the article provides the capture requirements and the kalibr_calibrate_cameras run command.